Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8ENT

Interleukin-21 signaling complex with IL-21R and IL-2Rg

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL12-2
Synchrotron siteSSRL
BeamlineBL12-2
Temperature [K]100
Detector technologyPIXEL
Collection date2021-02-04
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9795
Spacegroup nameP 1
Unit cell lengths66.167, 66.464, 162.684
Unit cell angles83.34, 83.71, 73.10
Refinement procedure
Resolution48.170 - 2.830
R-factor0.2551
Rwork0.254
R-free0.29970
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3tgx 2b5i
RMSD bond length0.002
RMSD bond angle0.589
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHENIX
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.1702.932
High resolution limit [Å]2.8302.831
Rpim0.129
Number of reflections577545757
<I/σ(I)>4.22
Completeness [%]91.7
Redundancy3.7
CC(1/2)0.9850.401
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP82950.1M Tris pH 8, 20% PEG 6000

219869