Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7SQB

PPAR gamma LBD bound to Inverse Agonist SR10221

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyPIXEL
Collection date2018-10-25
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9537
Spacegroup nameP 65 2 2
Unit cell lengths65.854, 65.854, 363.331
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution48.300 - 2.600
R-factor0.2264
Rwork0.225
R-free0.26080
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6c5q
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.16_3549)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]48.30048.3002.720
High resolution limit [Å]2.6009.0102.600
Rmerge0.2070.0369.900
Rmeas0.2100.03713.464
Rpim0.0340.0072.162
Total number of observations573246
Number of reflections155655021818
<I/σ(I)>16.1
Completeness [%]100.099.499.9
Redundancy36.826.738.2
CC(1/2)0.9990.9980.414
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.82894.25M Ammonium acetate, 0.1M Bis Tris Propane pH 6.8

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon