7BI2
PI3KC2aDeltaN and DeltaC-C2
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | BESSY BEAMLINE 14.1 |
| Synchrotron site | BESSY |
| Beamline | 14.1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-05-12 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 0.9184 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 82.557, 115.887, 144.365 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 49.200 | 3.450 |
| High resolution limit [Å] | 3.250 | 3.250 |
| Rmeas | 0.152 | 2.294 |
| Number of reflections | 22257 | 3455 |
| <I/σ(I)> | 9.73 | 0.84 |
| Completeness [%] | 99.1 | 97.1 |
| Redundancy | 4.9 | 4.9 |
| CC(1/2) | 0.998 | 0.443 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 298 | 0.1MTris, 8% PEG20000, 10% ethylene glycol, 10% formamide |