Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6U2G

BRAF-MEK complex with AMP-PCP bound to BRAF

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 5.0.2
Synchrotron siteALS
Beamline5.0.2
Temperature [K]80
Detector technologyPIXEL
Collection date2018-09-12
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.99999
Spacegroup nameP 31 2 1
Unit cell lengths117.420, 117.420, 130.273
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution80.159 - 2.886
R-factor0.2313
Rwork0.229
R-free0.27570
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4mne
RMSD bond length0.016
RMSD bond angle1.324
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.12-2829_final)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]80.1592.989
High resolution limit [Å]2.8862.886
Rmerge0.0230.319
Number of reflections236132337
<I/σ(I)>17.852.08
Completeness [%]99.099.96
Redundancy2
CC(1/2)1.0000.786
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.5293Ammonium sulfate, MES, PEK 8000

224201

PDB entries from 2024-08-28

PDB statisticsPDBj update infoContact PDBjnumon