6IWD
The PTP domain of human PTPN14 in a complex with the CR3 domain of HPV18 E7
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 5C (4A) |
| Synchrotron site | PAL/PLS |
| Beamline | 5C (4A) |
| Temperature [K] | 93 |
| Detector technology | CCD |
| Collection date | 2017-09-26 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.987 |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 54.573, 169.153, 42.530 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 29.987 - 1.800 |
| R-factor | 0.1873 |
| Rwork | 0.186 |
| R-free | 0.21250 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2bzl |
| RMSD bond length | 0.007 |
| RMSD bond angle | 0.774 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | MOLREP |
| Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.830 |
| High resolution limit [Å] | 1.800 | 1.800 |
| Rmerge | 0.087 | 0.328 |
| Number of reflections | 35719 | 1615 |
| <I/σ(I)> | 41.3 | |
| Completeness [%] | 95.1 | |
| Redundancy | 7.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 291 | 0.1 M Tris-HCl pH 8.0, 25% (w/v) polyethylene glycol 3350, 0.25 M lithium sulfate monohydrate, and 2% (v/v) tert-butanol |