6GZY
HOIP-fragment5 complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I03 |
| Synchrotron site | Diamond |
| Beamline | I03 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2017-05-21 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 0.9762 |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 111.202, 117.249, 37.940 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 80.685 - 2.150 |
| R-factor | 0.2009 |
| Rwork | 0.199 |
| R-free | 0.24600 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4ljo |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.590 |
| Data reduction software | XDS |
| Data scaling software | autoPROC |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.13_2998: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 117.250 | 1.990 |
| High resolution limit [Å] | 1.800 | 1.800 |
| Rmerge | 0.173 | 1.174 |
| Number of reflections | 22028 | |
| <I/σ(I)> | 8.2 | |
| Completeness [%] | 91.6 | |
| Redundancy | 6.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8.5 | 291 | 0.1 M Tris HCl pH 8.5, 28% w/v PEG 4000, 0.2 M Li2SO4 |