6FP6
Complex of human Cu,Zn SOD1 with the human copper chaperone for SOD1 in a compact conformation
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 1 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2016-09-26 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.97857 |
Spacegroup name | P 32 |
Unit cell lengths | 181.054, 181.054, 141.102 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.010 | 3.100 |
High resolution limit [Å] | 2.940 | 2.940 |
Rmerge | 0.165 | 0.944 |
Number of reflections | 110021 | |
<I/σ(I)> | 8.5 | 1.9 |
Completeness [%] | 100.0 | 100 |
Redundancy | 5.9 | 5.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.1 M PCTP buffer pH 9.0, 20% (w/v) PEG 3350. |