Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6YF2

FKBP12 in complex with the BMP potentiator compound 6 at 1.03A resolution

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X10SA
Synchrotron siteSLS
BeamlineX10SA
Temperature [K]100
Detector technologyPIXEL
Collection date2016-02-19
DetectorPSI PILATUS 6M
Wavelength(s)0.99996
Spacegroup nameP 42 21 2
Unit cell lengths57.482, 57.482, 54.469
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.770 - 1.030
R-factor0.1413
Rwork0.141
R-free0.14880
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4dh0
RMSD bond length0.007
RMSD bond angle1.369
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwareREFMAC (5.5.0063)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]19.7701.060
High resolution limit [Å]1.0301.030
Rmerge0.0440.140
Rmeas0.0460.166
Number of reflections445752585
<I/σ(I)>32.86.3
Completeness [%]97.678.4
Redundancy10.73.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2981.9 M AmSO4, 0.15 M CdCl2

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon