6BVA
Ubiquitin Variant (UbV.Fl10.1) bound to a human Skp1-Fbl10 fragment complex.
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 93.15 |
Detector technology | PIXEL |
Collection date | 2016-11-21 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.97910 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 65.360, 81.793, 128.685 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 47.460 - 2.660 |
R-factor | 0.218 |
Rwork | 0.216 |
R-free | 0.26300 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1ubq 5ibk 5jh5 |
RMSD bond length | 0.006 |
RMSD bond angle | 0.881 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((1.12_2829: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.760 |
High resolution limit [Å] | 2.660 | 2.660 |
Number of reflections | 20716 | |
<I/σ(I)> | 16.5 | 2.2 |
Completeness [%] | 99.8 | 99.9 |
Redundancy | 5.3 | 4.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 0.1 M Hepes pH 7.5, 0.2 M calcium chloride, 18% (w/v) PEG 6000 |