Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5UVV

BRD4 Bromodomain 2 with A-1457066

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2016-10-13
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)1.0
Spacegroup nameP 1 21 1
Unit cell lengths33.465, 85.769, 40.551
Unit cell angles90.00, 111.40, 90.00
Refinement procedure
Resolution17.480 - 1.990
R-factor0.247
Rwork0.245
R-free0.30100
RMSD bond length0.007
RMSD bond angle0.830
Data reduction softwareXDS (2.11.7)
Data scaling softwareSCALA
Refinement softwareBUSTER (2.11.7)
Data quality characteristics
 Overall
Low resolution limit [Å]34.550
High resolution limit [Å]1.990
Rmerge0.049
Number of reflections14372
<I/σ(I)>13.4
Completeness [%]98.5
Redundancy3.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION277Protein Buffer : 10 mM HEPES PH 7.5 100 mM NaCl 5mM DTT Crystallization : 15 % (v/v) Ethanol Tris PH 7.0

222415