5GTM
Modified human MxA, nucleotide-free form
Experimental procedure
Experimental method | MAD |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-04-02 |
Detector | RAYONIX MX-225 |
Wavelength(s) | 0.97946 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 104.180, 60.160, 153.920 |
Unit cell angles | 90.00, 98.62, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 39.200 | 3.000 |
High resolution limit [Å] | 2.896 | 2.900 |
Rmerge | 0.122 | |
Number of reflections | 42599 | |
<I/σ(I)> | 11.2 | |
Completeness [%] | 98.8 | |
Redundancy | 3.52 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291 | 100mM ammonium citrate tribasic (pH 7.0), 12% PEG 3350 |