5EEQ
Grb7 SH2 with the G7-B1 bicyclic peptide inhibitor
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
| Synchrotron site | Australian Synchrotron |
| Beamline | MX2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2010-10-16 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.954 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 37.081, 63.811, 52.040 |
| Unit cell angles | 90.00, 92.50, 90.00 |
Refinement procedure
| Resolution | 40.306 - 1.600 |
| R-factor | 0.1746 |
| Rwork | 0.173 |
| R-free | 0.19610 |
| RMSD bond length | 0.005 |
| RMSD bond angle | 0.935 |
| Data reduction software | XDS |
| Data scaling software | SCALA |
| Phasing software | MOLREP |
| Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 40.310 |
| High resolution limit [Å] | 1.600 |
| Number of reflections | 31961 |
| Completeness [%] | 99.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.1 M bis-tris pH 5.5, 25% (w/v) PEG 3350 |