5E4E
Engineered Interleukin-13 bound to receptor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.2 |
Synchrotron site | ALS |
Beamline | 5.0.2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-10-21 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 1.0 |
Spacegroup name | P 21 2 21 |
Unit cell lengths | 62.590, 69.370, 186.800 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 38.740 - 3.000 |
R-factor | 0.2366 |
Rwork | 0.234 |
R-free | 0.28850 |
RMSD bond length | 0.002 |
RMSD bond angle | 0.526 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 38.740 |
High resolution limit [Å] | 3.000 |
Number of reflections | 16583 |
<I/σ(I)> | 15.6 |
Completeness [%] | 99.2 |
Redundancy | 4.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 4.2 | 293 | lithium sulfate, phosphate/citrate pH 4.2, PEG 1000 |