Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4Y5Y

Diabody 330 complex with EpoR

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL12-2
Synchrotron siteSSRL
BeamlineBL12-2
Temperature [K]100
Detector technologyPIXEL
Collection date2013-06-06
DetectorPSI PILATUS 6M
Wavelength(s)0.9795
Spacegroup nameP 2 21 21
Unit cell lengths78.141, 95.799, 144.972
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution43.146 - 2.850
Rwork0.221
R-free0.24080
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3s34 1eer
Data scaling softwareAimless (0.2.17)
Phasing softwarePHASER
Refinement softwarePHENIX
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]48.32048.3202.905
High resolution limit [Å]2.8509.0102.850
Rmerge0.1000.0260.727
Rpim0.0540.0150.383
Total number of observations110916328916790
Number of reflections25898
<I/σ(I)>11.132.91.9
Completeness [%]99.497.199.9
Redundancy4.33.74.5
CC(1/2)0.9970.9990.781
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION7293Magnesium chloride, Tris, PEG 8000

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon