2I5X
Engineering the PTPbeta catalytic domain with improved crystallization properties
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2004-01-01 |
Detector | MARRESEARCH |
Wavelength(s) | 1 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 61.973, 71.308, 69.690 |
Unit cell angles | 90.00, 93.40, 90.00 |
Refinement procedure
Resolution | 39.600 - 1.700 |
R-factor | 0.18 |
Rwork | 0.179 |
R-free | 0.20700 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2i4h |
RMSD bond length | 0.007 |
RMSD bond angle | 0.920 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | AMoRE |
Refinement software | REFMAC |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 39.600 | 1.800 |
High resolution limit [Å] | 1.700 | 1.700 |
Rmerge | 0.036 | 0.300 |
Number of reflections | 66068 | |
<I/σ(I)> | 16.98 | 3.64 |
Completeness [%] | 99.6 | 97.9 |
Redundancy | 3.9 | 2.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 298 | 21% PEG 8000, 220 mM MgCl2, 1% BME, 0.1% BOG, 5mM DTT, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K |