9D7Q
Water and chloride as allosteric inhibitors in WNK kinase osmosensing
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL12-2 |
Synchrotron site | SSRL |
Beamline | BL12-2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2024-05-06 |
Detector | DECTRIS EIGER2 X 16M |
Wavelength(s) | 0.9795 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 50.170, 113.596, 67.524 |
Unit cell angles | 90.00, 101.36, 90.00 |
Refinement procedure
Resolution | 43.107 - 3.301 |
Rwork | 0.177 |
R-free | 0.26980 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.004 |
RMSD bond angle | 1.617 |
Data reduction software | HKL-3000 |
Data scaling software | HKL-3000 |
Phasing software | MOLREP |
Refinement software | REFMAC (5.8.0425) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 43.107 | 3.360 |
High resolution limit [Å] | 3.300 | 3.300 |
Number of reflections | 7872 | 50 |
<I/σ(I)> | 9.8 | |
Completeness [%] | 75.0 | 55 |
Redundancy | 5.2 | |
CC(1/2) | 0.960 | 0.600 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.4 | 289 | 8% Tacsimate, 10% PEG3350 |