8USR
IL17A homodimer complexed to Compound 23
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-01-30 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.00 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 62.110, 159.090, 107.180 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 32.590 - 1.830 |
R-factor | 0.2217 |
Rwork | 0.220 |
R-free | 0.25030 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.133 |
Data reduction software | autoPROC |
Data scaling software | autoPROC |
Phasing software | PHASER |
Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 79.500 | 1.963 |
High resolution limit [Å] | 1.830 | 1.831 |
Number of reflections | 45560 | 1901 |
<I/σ(I)> | 7.4 | |
Completeness [%] | 80.7 | |
Redundancy | 5.7 | |
CC(1/2) | 1.000 | 0.579 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 290 | 2 M NaCl, 0.1 M NaH2PO4, 0.1 M KH2PO4, 0.1 M MES pH 6.5 |