8TMU
HLA-B*73:01 bound to a 10mer peptide in complex with KIR2DL2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-B |
Synchrotron site | APS |
Beamline | 23-ID-B |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-12-20 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.03320 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 92.690, 92.690, 200.980 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 54.300 - 2.900 |
R-factor | 0.2177 |
Rwork | 0.215 |
R-free | 0.25770 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.003 |
RMSD bond angle | 0.550 |
Data reduction software | iMOSFLM (7.4.0) |
Data scaling software | Aimless (0.7.7) |
Phasing software | PHASER (1.20.1_4487+SVN) |
Refinement software | PHENIX (1.20.1_4487+SVN) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 54.300 | 3.004 |
High resolution limit [Å] | 2.900 | 2.900 |
Number of reflections | 20180 | 1973 |
<I/σ(I)> | 11.9 | |
Completeness [%] | 100.0 | 100 |
Redundancy | 16.8 | |
CC(1/2) | 1.000 | 0.411 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | Tris-HCl pH 8.75 and 20% PEG 8000 |