8ISN
HLA-A24 in complex with modified 9mer WT1 peptide
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SPRING-8 BEAMLINE BL45XU |
Synchrotron site | SPring-8 |
Beamline | BL45XU |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-12-02 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 1.0000 |
Spacegroup name | F 2 2 2 |
Unit cell lengths | 161.400, 166.130, 180.530 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 49.240 - 2.480 |
R-factor | 0.2241 |
Rwork | 0.222 |
R-free | 0.25750 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.003 |
RMSD bond angle | 0.511 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.630 |
High resolution limit [Å] | 2.480 | 2.480 |
Number of reflections | 42937 | 6885 |
<I/σ(I)> | 11.8 | 0.97 |
Completeness [%] | 100.0 | |
Redundancy | 18 | |
CC(1/2) | 0.997 | 0.514 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.2 M Ammonium tartrate dibasic, 20 % (w/v) PEG 3350 |