Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8FVF

Bromodomain of EP300 liganded with CCS-1477

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-BM
Synchrotron siteAPS
Beamline22-BM
Temperature [K]93
Detector technologyCCD
Collection date2020-06-20
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)1.0000
Spacegroup nameP 4 21 2
Unit cell lengths103.150, 103.150, 59.220
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.740 - 2.100
R-factor0.1844
Rwork0.181
R-free0.23890
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.157
Data reduction softwareXDS (Jan 31, 2020)
Data scaling softwareXSCALE
Phasing softwarePHENIX
Refinement softwarePHENIX (1.20.1-4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]19.7402.200
High resolution limit [Å]2.1002.100
Rmeas0.1750.880
Number of reflections191852449
<I/σ(I)>163.5
Completeness [%]99.8100
Redundancy13.413.7
CC(1/2)0.9980.891
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.52910.1M Sodium chloride, 0.1M HEPES pH7.5, 1.6M Ammonium sulfate

227111

PDB entries from 2024-11-06

PDB statisticsPDBj update infoContact PDBjnumon