Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8F8M

LRH-1 bound to small molecule Tet and fragment of coactivator Tif2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]80
Detector technologyPIXEL
Collection date2022-02-20
DetectorDECTRIS EIGER X 16M
Wavelength(s)1
Spacegroup nameP 32 2 1
Unit cell lengths89.161, 89.161, 105.692
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution44.580 - 2.600
R-factor0.2033
Rwork0.196
R-free0.21960
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4dos
RMSD bond length0.002
RMSD bond angle0.480
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX (1.14_3260)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]44.6002.690
High resolution limit [Å]2.6002.600
Number of reflections150661235
<I/σ(I)>12.11.38
Completeness [%]97.7
Redundancy11.2
CC(1/2)0.9370.570
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP277.15tri-Na citrate, tert-butanol, glycerol

226707

PDB entries from 2024-10-30