8EZL

Pfs25 in complex with transmission-reducing antibody AS01-50

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-B
Synchrotron siteAPS
Beamline23-ID-B
Temperature [K]100
Detector technologyPIXEL
Collection date2020-12-01
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.033132
Spacegroup nameC 1 2 1
Unit cell lengths88.610, 55.750, 86.090
Unit cell angles90.00, 103.63, 90.00
Refinement procedure
Resolution46.800 - 2.300
R-factor0.2195
Rwork0.215
R-free0.25540
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6phb
RMSD bond length0.002
RMSD bond angle0.515
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.14.3260)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]46.8002.382
High resolution limit [Å]2.3002.300
Rpim0.0370.301
Number of reflections180261731
<I/σ(I)>14.132.25
Completeness [%]98.394.75
Redundancy3.42.8
CC(1/2)0.9980.815
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52910.1M lithium chloride, 0.1M HEPES pH 7.5, and 25% PEG 6000