Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8DF1

Chi3l1 bound by antibody C59

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 5.0.1
Synchrotron siteALS
Beamline5.0.1
Temperature [K]80
Detector technologyPIXEL
Collection date2020-03-15
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.97
Spacegroup nameP 21 21 21
Unit cell lengths102.100, 172.920, 404.480
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution87.290 - 3.300
Rwork0.206
R-free0.24320
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4p8v 6peh 4hbc
Data reduction softwareMOSFLM
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1-4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]87.2903.418
High resolution limit [Å]3.3003.300
Rmerge0.796
Number of reflections10860410701
<I/σ(I)>8.971.87
Completeness [%]99.999.8
Redundancy11.811.7
CC(1/2)0.421
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.5293.150.1M Tris pH 8.5, 10% PEG 4000, 2% MPD

227344

PDB entries from 2024-11-13

PDB statisticsPDBj update infoContact PDBjnumon