8B7W
Complex IL-17A/anti-IL-17A-76
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE MASSIF-3 |
Synchrotron site | ESRF |
Beamline | MASSIF-3 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-12-08 |
Detector | DECTRIS EIGER X 4M |
Wavelength(s) | 0.96770 |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 71.050, 71.050, 106.040 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.920 |
High resolution limit [Å] | 2.850 | 2.850 |
Rmeas | 0.270 | 1.970 |
Number of reflections | 7466 | 538 |
<I/σ(I)> | 12 | 1.58 |
Completeness [%] | 98.1 | 99.4 |
Redundancy | 6.7 | |
CC(1/2) | 0.960 | 0.460 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 297 | 1.05 M NaCl, 7% v/v ethanol, 30% glycerol. |