8B7W

Complex IL-17A/anti-IL-17A-76

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE MASSIF-3
Synchrotron siteESRF
BeamlineMASSIF-3
Temperature [K]100
Detector technologyPIXEL
Collection date2021-12-08
DetectorDECTRIS EIGER X 4M
Wavelength(s)0.96770
Spacegroup nameP 31 2 1
Unit cell lengths71.050, 71.050, 106.040
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution40.170 - 2.850
R-factor0.2237
Rwork0.222
R-free0.26490
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4hr9 6rbb
RMSD bond length0.010
RMSD bond angle1.137
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0258)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.920
High resolution limit [Å]2.8502.850
Rmeas0.2701.970
Number of reflections7466538
<I/σ(I)>121.58
Completeness [%]98.199.4
Redundancy6.7
CC(1/2)0.9600.460
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2971.05 M NaCl, 7% v/v ethanol, 30% glycerol.

222926