8B7W
Complex IL-17A/anti-IL-17A-76
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE MASSIF-3 |
| Synchrotron site | ESRF |
| Beamline | MASSIF-3 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-12-08 |
| Detector | DECTRIS EIGER X 4M |
| Wavelength(s) | 0.96770 |
| Spacegroup name | P 31 2 1 |
| Unit cell lengths | 71.050, 71.050, 106.040 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.920 |
| High resolution limit [Å] | 2.850 | 2.850 |
| Rmeas | 0.270 | 1.970 |
| Number of reflections | 7466 | 538 |
| <I/σ(I)> | 12 | 1.58 |
| Completeness [%] | 98.1 | 99.4 |
| Redundancy | 6.7 | |
| CC(1/2) | 0.960 | 0.460 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 297 | 1.05 M NaCl, 7% v/v ethanol, 30% glycerol. |