8USS
IL17A complexed to Compound 7
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 17-ID |
| Synchrotron site | APS |
| Beamline | 17-ID |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2018-02-14 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 1.00 |
| Spacegroup name | I 2 2 2 |
| Unit cell lengths | 36.600, 50.380, 157.360 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 15.780 - 1.470 |
| R-factor | 0.222 |
| Rwork | 0.221 |
| R-free | 0.23550 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.023 |
| RMSD bond angle | 2.092 |
| Data reduction software | autoPROC |
| Data scaling software | autoPROC |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 78.700 | 1.526 |
| High resolution limit [Å] | 1.465 | 1.465 |
| Number of reflections | 21942 | 1098 |
| <I/σ(I)> | 21.9 | |
| Completeness [%] | 85.6 | |
| Redundancy | 5.1 | |
| CC(1/2) | 1.000 | 0.880 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 296 | 15% w/v PEG 8K, 0.2 M MgCl2, 0.1 M Tris pH 8.5 |