7THO
Integrin alpha IIB beta3 complex with Eptifibatide
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-B |
Synchrotron site | APS |
Beamline | 23-ID-B |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-07-03 |
Detector | MARMOSAIC 300 mm CCD |
Wavelength(s) | 0.97948 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 260.340, 145.040, 104.870 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.440 - 2.750 |
R-factor | 0.1893 |
Rwork | 0.189 |
R-free | 0.22240 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3nig |
RMSD bond length | 0.003 |
RMSD bond angle | 0.548 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.820 |
High resolution limit [Å] | 2.750 | 2.750 |
Rmerge | 0.114 | 1.634 |
Number of reflections | 103704 | 7566 |
<I/σ(I)> | 10.4 | |
Completeness [%] | 99.9 | |
Redundancy | 5.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 297 | 11-13% PEG 8000, 0.2 M Ammonium Sulfate, 0.1 M Tris-HCl, pH 8.9 |