7SHZ
IgE-Fc in complex with HAE
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL9-2 |
Synchrotron site | SSRL |
Beamline | BL9-2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-12-13 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.979460 |
Spacegroup name | I 1 2 1 |
Unit cell lengths | 93.340, 187.340, 148.834 |
Unit cell angles | 90.00, 103.13, 90.00 |
Refinement procedure
Resolution | 47.350 - 3.000 |
R-factor | 0.1882 |
Rwork | 0.186 |
R-free | 0.23550 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5hys |
RMSD bond length | 0.007 |
RMSD bond angle | 0.954 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX |
Refinement software | PHENIX (1.19.1_4122) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.353 | 3.100 |
High resolution limit [Å] | 3.000 | 3.000 |
Number of reflections | 48998 | 4592 |
<I/σ(I)> | 12.94 | |
Completeness [%] | 98.2 | |
Redundancy | 3.4 | |
CC(1/2) | 0.998 | 0.844 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.1 M Sodium acetate pH 4.6, 8% (w/v) PEG 4000 |