Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7OY1

DnrK mutant RTCR

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsMAX IV BEAMLINE BioMAX
Synchrotron siteMAX IV
BeamlineBioMAX
Temperature [K]100
Detector technologyPIXEL
Collection date2019-10-05
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.987
Spacegroup nameP 1 21 1
Unit cell lengths60.400, 105.690, 64.450
Unit cell angles90.00, 111.18, 90.00
Refinement procedure
Resolution49.700 - 2.390
R-factor0.2293
Rwork0.227
R-free0.26680
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1tw2
RMSD bond length0.009
RMSD bond angle1.179
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHENIX
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]49.7102.480
High resolution limit [Å]2.3902.390
Rmerge0.242
Rmeas0.138
Rpim0.169
Number of reflections296362854
<I/σ(I)>4.1
Completeness [%]99.1
Redundancy3.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP293.150.2 M Magnesium chloride hexahydrate; 0.1 M HEPES 7.0; 20 % w/v PEG 6000