7OX4
Mouse interleukin-9 in complex with Fab 35D8.
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PETRA III, EMBL c/o DESY BEAMLINE P13 (MX1) |
| Synchrotron site | PETRA III, EMBL c/o DESY |
| Beamline | P13 (MX1) |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-04-28 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.9762 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 70.210, 78.920, 192.100 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 48.020 | 1.910 |
| High resolution limit [Å] | 1.800 | 1.800 |
| Number of reflections | 49669 | 7855 |
| <I/σ(I)> | 9.49 | |
| Completeness [%] | 99.7 | |
| Redundancy | 5.8 | |
| CC(1/2) | 0.997 | 0.443 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.2M Zinc acetate, 23% PEG 3350 |