7OUV
Crystal structure of human filamin C domains 14-15 cardiovascular disease causing mutation S1624L
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04 |
Synchrotron site | Diamond |
Beamline | I04 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-02-01 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.9795 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 39.133, 70.498, 156.937 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 39.230 - 1.800 |
R-factor | 0.2136 |
Rwork | 0.213 |
R-free | 0.24020 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | unreleased |
RMSD bond length | 0.004 |
RMSD bond angle | 0.675 |
Data reduction software | XDS |
Data scaling software | XDS (1.19.2_4158) |
Phasing software | PHASER |
Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 39.230 | 1.864 |
High resolution limit [Å] | 1.800 | 1.800 |
Rmerge | 0.147 | 2.913 |
Rmeas | 0.153 | 3.027 |
Rpim | 0.044 | 0.816 |
Number of reflections | 41232 | 4057 |
<I/σ(I)> | 9.99 | 0.76 |
Completeness [%] | 99.6 | 99.8 |
Redundancy | 12.6 | |
CC(1/2) | 0.998 | 0.478 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 5 | 295.15 | 0.1 M SPG pH 5.0, 25% w/v PEG 1500 |