Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-11-13 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.979 |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 117.334, 117.334, 130.004 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 43.550 - 3.090 |
R-factor | 0.1967 |
Rwork | 0.195 |
R-free | 0.23320 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6pp9 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.18.2_3874) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 43.552 | 3.200 |
High resolution limit [Å] | 3.090 | 3.090 |
Rmerge | 0.126 | |
Rmeas | 0.131 | |
Rpim | 0.034 | |
Number of reflections | 19401 | 1901 |
<I/σ(I)> | 18.68 | 1.59 |
Completeness [%] | 99.9 | |
Redundancy | 14.1 | |
CC(1/2) | 1.000 | 0.660 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100 mM Tris 8.5, 200 mM Lithium Sulfate and 22% PEG 3,350 |