7DR4
Complex of anti-human IL-2 antibody and human IL-2
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 11C |
| Synchrotron site | PAL/PLS |
| Beamline | 11C |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-10-21 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 0.9794 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 79.334, 72.261, 210.930 |
| Unit cell angles | 90.00, 92.71, 90.00 |
Refinement procedure
| Resolution | 29.790 - 2.490 |
| R-factor | 0.1964 |
| Rwork | 0.195 |
| R-free | 0.25770 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 5lqb |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.014 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX (1.17.1_3660) |
| Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 48.250 | 2.500 |
| High resolution limit [Å] | 2.490 | 2.500 |
| Rmeas | 0.179 | |
| Rpim | 0.083 | |
| Number of reflections | 80414 | 5025 |
| <I/σ(I)> | 1.34 | |
| Completeness [%] | 96.3 | |
| Redundancy | 4.3 | |
| CC(1/2) | 0.980 | 0.442 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.2M NH4NO3, pH4.8, 25% PEG3350 |