Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7BI9

PI3KC2a core in complex with PIK90

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2020-10-17
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.9184
Spacegroup nameP 21 21 21
Unit cell lengths55.943, 135.397, 151.603
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.940 - 2.650
R-factor0.235
Rwork0.233
R-free0.27980
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7bi4
RMSD bond length0.002
RMSD bond angle1.205
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0258)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.9402.810
High resolution limit [Å]2.6502.650
Rmeas0.1252.129
Number of reflections330995274
<I/σ(I)>11.16
Completeness [%]96.296.3
Redundancy4
CC(1/2)0.9980.380
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.52980.1MTris, 8-6% PEG3350, 0.2-0.1M MgSO4

220113

PDB entries from 2024-05-22