7ALC

human GCH-GFRP stimulatory complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2018-09-12
DetectorDECTRIS EIGER X 16M
Wavelength(s)1
Spacegroup nameC 1 2 1
Unit cell lengths163.853, 113.922, 113.910
Unit cell angles90.00, 130.21, 90.00
Refinement procedure
Resolution86.990 - 1.726
R-factor0.1979
Rwork0.197
R-free0.22730
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1is8
RMSD bond length0.008
RMSD bond angle0.980
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareBUSTER (2.11.7 (18-SEP-2020))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]86.9901.934
High resolution limit [Å]1.7261.726
Number of reflections16288844799
<I/σ(I)>7.9
Completeness [%]99.199.7
Redundancy3.5
CC(1/2)0.9980.260
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6293.152 M NaCl; 0.1 M NaCit pH 6.0

237735