Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7WSL

PD-1 in complex with Dostarlimab

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPAL/PLS BEAMLINE 5C (4A)
Synchrotron sitePAL/PLS
Beamline5C (4A)
Temperature [K]100
Detector technologyPIXEL
Collection date2021-11-30
DetectorDECTRIS EIGER X 9M
Wavelength(s)0.97949
Spacegroup nameP 1
Unit cell lengths39.600, 44.870, 76.960
Unit cell angles93.80, 98.18, 97.95
Refinement procedure
Resolution28.543 - 1.534
R-factor0.1615
Rwork0.161
R-free0.17830
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5ggs
Data reduction softwareXDS
Data scaling softwareHKL-2000
Phasing softwareREFMAC
Refinement softwarePHENIX (1.13_2998)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]28.5431.590
High resolution limit [Å]1.5301.530
Number of reflections738357304
<I/σ(I)>14.5
Completeness [%]95.3
Redundancy3.7
CC(1/2)0.9970.945
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2930.2M trimethylamine N-oxide dihydrate, 0.1M Tris pH 8.5, 20% w/v PEG 3350

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon