7WKX
IL-17A in complex with the humanized antibody HB0017
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NFPSS BEAMLINE BL19U1 |
Synchrotron site | NFPSS |
Beamline | BL19U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-04-30 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 1.03923 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 301.142, 50.829, 117.216 |
Unit cell angles | 90.00, 101.27, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.850 |
High resolution limit [Å] | 2.800 | 2.800 |
Rmerge | 0.067 | 0.067 |
Number of reflections | 41319 | |
<I/σ(I)> | 15.5 | 2.2 |
Completeness [%] | 96.5 | |
Redundancy | 2.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 291 | 4% v/v Tacsimate pH 7.0, 12% w/v Polyethylene glycol 3,350 |