Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7QUH

Siglec-8 in complex with therapeutic Fab AK002.

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06DA
Synchrotron siteSLS
BeamlineX06DA
Temperature [K]100
Detector technologyPIXEL
Collection date2021-04-29
DetectorDECTRIS PILATUS 2M-F
Wavelength(s)1.00003
Spacegroup nameC 1 2 1
Unit cell lengths145.343, 44.554, 111.387
Unit cell angles90.00, 111.41, 90.00
Refinement procedure
Resolution42.319 - 2.867
R-factor0.2277
Rwork0.225
R-free0.28360
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7qu6
Data reduction softwareautoPROC
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.14_3260)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]42.3202.970
High resolution limit [Å]2.8672.870
Rmerge0.2331.042
Rpim0.0970.446
Number of reflections149351575
<I/σ(I)>9.3
Completeness [%]95.4
Redundancy6.7
CC(1/2)0.9850.678
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2910.2M ammonium chloride 20% PEG3350 pH6.3

219869

PDB entries from 2024-05-15