7OX2

Fab 6E2: hIL-9 complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-01-29
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.97242
Spacegroup nameP 1
Unit cell lengths69.358, 94.364, 107.331
Unit cell angles82.54, 72.00, 80.79
Refinement procedure
Resolution48.920 - 3.340
R-factor0.2268
Rwork0.224
R-free0.28350
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6ghg 5y9j
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.17.1_3660)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.9203.540
High resolution limit [Å]3.3403.340
Number of reflections346385336
<I/σ(I)>4.78
Completeness [%]93.6
Redundancy2.9
CC(1/2)0.9600.517
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP3.82930.2M lithium sulfate, 0.1M phosphate/ citric acid, pH 3.8

239149