7KJU

Cgi121-tRNA complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]100
Detector technologyPIXEL
Collection date2013-11-21
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.97964
Spacegroup nameC 2 2 2
Unit cell lengths100.493, 168.527, 68.968
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution49.030 - 3.100
R-factor0.2283
Rwork0.227
R-free0.24590
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3l0u
RMSD bond length0.002
RMSD bond angle0.452
Data reduction softwareDIALS (1.14.5)
Data scaling softwareAimless (0.7.4)
Phasing softwarePHASER (2.8.3)
Refinement softwarePHENIX ((1.21.1_5286: ???))
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]49.14049.1403.190
High resolution limit [Å]3.10013.9103.110
Rmerge0.0810.0360.931
Rmeas0.0850.0380.989
Rpim0.0250.0120.330
Total number of observations12117016
Number of reflections10895127792
<I/σ(I)>13.336.82.1
Completeness [%]99.987.2100
Redundancy11.89.58.9
CC(1/2)0.9990.9990.956
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6293100 mM MES, pH 6.0, 0.2 M zinc acetate, 10% PEG8000