Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7JIU

HUMAN PI3KDELTA IN COMPLEX WITH COMPOUND 2F

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2014-09-14
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.00003
Spacegroup nameP 21 21 21
Unit cell lengths58.457, 135.132, 142.045
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution97.910 - 2.120
R-factor0.2127
Rwork0.212
R-free0.24590
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)PREVIOUSLY DETERMINED STRUCTURE
RMSD bond length0.009
RMSD bond angle1.269
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0049)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]97.9102.370
High resolution limit [Å]2.1202.120
Rmeas0.0710.614
Number of reflections6462018062
<I/σ(I)>19.43.99
Completeness [%]99.899.5
Redundancy8.18.4
CC(1/2)0.9990.999
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION293NOT AVAILABLE

219869

PDB entries from 2024-05-15