6YSC
GLYCOSYLATED KNOB-HOLE/DUMMY FC FRAGMENT
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X10SA |
Synchrotron site | SLS |
Beamline | X10SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-07-05 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 1.0000 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 49.361, 80.357, 141.826 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 71.010 - 2.050 |
Rwork | 0.230 |
R-free | 0.29286 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5hy9 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0230) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 71.010 | 2.210 |
High resolution limit [Å] | 2.050 | 2.050 |
Rpim | 0.024 | 0.423 |
Number of reflections | 24877 | 1310 |
<I/σ(I)> | 17.4 | 1.5 |
Completeness [%] | 94.8 | |
Redundancy | 6.5 | |
CC(1/2) | 1.000 | 0.640 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7 | 294 | 15% (w/v) PEG4000, 0.1M HEPES |