Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6YSC

GLYCOSYLATED KNOB-HOLE/DUMMY FC FRAGMENT

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X10SA
Synchrotron siteSLS
BeamlineX10SA
Temperature [K]100
Detector technologyPIXEL
Collection date2018-07-05
DetectorDECTRIS PILATUS3 6M
Wavelength(s)1.0000
Spacegroup nameP 21 21 21
Unit cell lengths49.361, 80.357, 141.826
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution71.010 - 2.050
Rwork0.230
R-free0.29286
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5hy9
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0230)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]71.0102.210
High resolution limit [Å]2.0502.050
Rpim0.0240.423
Number of reflections248771310
<I/σ(I)>17.41.5
Completeness [%]94.8
Redundancy6.5
CC(1/2)1.0000.640
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP729415% (w/v) PEG4000, 0.1M HEPES

222624

PDB entries from 2024-07-17

PDB statisticsPDBj update infoContact PDBjnumon