6WI3
Histone deacetylases complex with peptide macrocycles
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 21-ID-F |
| Synchrotron site | APS |
| Beamline | 21-ID-F |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2018-02-15 |
| Detector | RAYONIX MX300-HS |
| Wavelength(s) | 0.97648 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 92.162, 97.593, 139.070 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 48.800 - 2.350 |
| R-factor | 0.1995 |
| Rwork | 0.197 |
| R-free | 0.25400 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4lxz |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.18rc2_3793) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 48.800 | 2.420 |
| High resolution limit [Å] | 2.350 | 2.350 |
| Number of reflections | 52926 | 4539 |
| <I/σ(I)> | 8.7 | 1.2 |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 7.4 | 7.5 |
| CC(1/2) | 0.993 | 0.516 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 40% (v/v) PEG600 and 100mM CHES pH 9.5 |