Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6VRU

PIM-inhibitor complex 1

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-F
Synchrotron siteAPS
Beamline21-ID-F
Temperature [K]100
Detector technologyCCD
Collection date2009-02-02
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.979
Spacegroup nameP 65
Unit cell lengths98.555, 98.555, 81.009
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution50.000 - 2.070
Rwork0.179
R-free0.20240
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1xr1
RMSD bond length0.005
RMSD bond angle0.852
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareCNX
Refinement softwareCNS
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.170
High resolution limit [Å]2.0702.070
Rmerge0.1100.950
Number of reflections261941018
<I/σ(I)>4.09
Completeness [%]95.8
Redundancy11.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION6.52770.1 M imidazole, 0.7 M Na Acetate, pH6.5

223790

PDB entries from 2024-08-14

PDB statisticsPDBj update infoContact PDBjnumon