6ULV
BRD4-BD1 in complex with the cyclic peptide 4.2_1
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-06-30 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.953700 |
Spacegroup name | P 65 2 2 |
Unit cell lengths | 112.288, 112.288, 235.579 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 47.620 - 2.200 |
R-factor | 0.2004 |
Rwork | 0.198 |
R-free | 0.23770 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4lyi |
RMSD bond length | 0.004 |
RMSD bond angle | 0.682 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.14_3260) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.620 | 2.270 |
High resolution limit [Å] | 2.200 | 2.200 |
Number of reflections | 45427 | 3838 |
<I/σ(I)> | 9.2 | |
Completeness [%] | 100.0 | |
Redundancy | 33.3 | |
CC(1/2) | 0.997 | 0.694 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291 | Sodium Iodide (150-250mM), PEG 3350 (15-25%) and 100mM Bis Tris Propane |