6QH6
AP2 clathrin adaptor core with two cargo peptides in open+ conformation
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I02 |
Synchrotron site | Diamond |
Beamline | I02 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-09-17 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.252 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 180.500, 180.500, 210.060 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 91.000 - 5.000 |
R-factor | 0.26043 |
Rwork | 0.259 |
R-free | 0.28519 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.010 |
RMSD bond angle | 1.525 |
Data reduction software | iMOSFLM |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0189) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 91.000 | 5.590 |
High resolution limit [Å] | 5.000 | 5.000 |
Rmerge | 0.202 | |
Rmeas | 0.247 | |
Rpim | 0.138 | |
Number of reflections | 15525 | |
<I/σ(I)> | 3.6 | |
Completeness [%] | 99.6 | |
Redundancy | 4.8 | |
CC(1/2) | 0.942 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.4 | 289 | 7.5% PVA, 9% 1-propanol, 90 mM Hepes pH 7.4, 100 mM guanidine hydrochloride |