6P88
E.coli LpxD in complex with compound 6
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 5.0.2 |
| Synchrotron site | ALS |
| Beamline | 5.0.2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2014-08-24 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 1.000 |
| Spacegroup name | P 32 2 1 |
| Unit cell lengths | 96.966, 96.966, 215.872 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 78.262 - 1.700 |
| R-factor | 0.1905 |
| Rwork | 0.189 |
| R-free | 0.21200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 3eh0 |
| Data reduction software | XDS |
| Data scaling software | SCALA (0.7.2) |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.14_3211) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 78.260 | 78.260 | 1.730 |
| High resolution limit [Å] | 1.700 | 9.310 | 1.700 |
| Rmerge | 0.079 | 0.025 | 1.317 |
| Rmeas | 0.085 | 0.027 | 1.408 |
| Rpim | 0.029 | 0.009 | 0.491 |
| Total number of observations | 987283 | 7223 | 52191 |
| Number of reflections | 119674 | 922 | 6349 |
| <I/σ(I)> | 15.4 | 46.3 | 1.5 |
| Completeness [%] | 92.1 | 99.5 | 100 |
| Redundancy | 8.2 | 7.8 | 8.2 |
| CC(1/2) | 0.999 | 1.000 | 0.628 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7 | 298 | 0.2M Mg formate, 20% PEG 3350 |