6OPH
phosphorylated ERK2 with GDC-0994
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU FR-E |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2012-03-28 |
Detector | RIGAKU RAXIS IV++ |
Wavelength(s) | 1.5418 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 42.070, 76.930, 151.760 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 26.590 - 2.400 |
R-factor | 0.19536 |
Rwork | 0.193 |
R-free | 0.24287 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2erk |
RMSD bond length | 0.007 |
RMSD bond angle | 1.616 |
Data reduction software | MOSFLM |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0238) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 2.530 |
High resolution limit [Å] | 2.400 | 2.400 |
Rmerge | 0.069 | 0.294 |
Rmeas | 0.319 | |
Rpim | 0.121 | |
Number of reflections | 17814 | 1835 |
<I/σ(I)> | 7.8 | |
Completeness [%] | 88.9 | 69.4 |
Redundancy | 5.9 | 6.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 9 | 293 | 36% PEG3350, 100mM bicine pH 9.0 |