Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6MZW

TAS-120 covalent complex with FGFR1

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyCCD
Collection date2018-02-15
DetectorADSC QUANTUM 315r
Wavelength(s)0.9537
Spacegroup nameC 1 2 1
Unit cell lengths208.919, 48.981, 65.119
Unit cell angles90.00, 106.19, 90.00
Refinement procedure
Resolution47.630 - 2.200
R-factor0.24379
Rwork0.241
R-free0.29695
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5ur1
RMSD bond length0.008
RMSD bond angle1.085
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0230)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]100.0002.270
High resolution limit [Å]2.2002.200
Number of reflections325312792
<I/σ(I)>7.3
Completeness [%]100.0100
Redundancy6.96.9
CC(1/2)0.9990.403
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP291MPEG 5000, ammonium sulfate, sodium cacodylate

222624