6MF2

Improved Model of Human Coagulation Factor VIII

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 5.0.1
Synchrotron siteALS
Beamline5.0.1
Temperature [K]100
Detector technologyCCD
Collection date2007-04-18
DetectorADSC QUANTUM 315
Wavelength(s)1.00
Spacegroup nameP 41 21 2
Unit cell lengths134.569, 134.569, 359.496
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution57.365 - 3.609
R-factor0.253947279805
Rwork0.252
R-free0.28356
RMSD bond length0.005
RMSD bond angle1.149
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwarePHENIX (1.12_2829)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]57.3653.738
High resolution limit [Å]3.6093.609
Number of reflections31887
<I/σ(I)>0.7
Completeness [%]81.7
Redundancy14
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52778-10% PEG8000, 0.1 M imidazole, 100-300 mM sodium chloride

219869