6MAM

Cleaved Ebola GP in complex with a broadly neutralizing human antibody, ADI-15946

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL12-2
Synchrotron siteSSRL
BeamlineBL12-2
Temperature [K]80
Detector technologyPIXEL
Collection date2016-07-06
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.97946
Spacegroup nameP 43 2 2
Unit cell lengths182.273, 182.273, 262.012
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.544 - 4.100
R-factor0.2684
Rwork0.262
R-free0.28100
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5hj3
RMSD bond length0.002
RMSD bond angle0.587
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.10.1_2155)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.5444.300
High resolution limit [Å]4.1004.100
Number of reflections353123460
<I/σ(I)>14.61.8
Completeness [%]99.6100
Redundancy13.113.4
CC(1/2)1.0000.700
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION8.22950.2 M sodium citrate tribasic dihydrate, 20% polyethelyene glycol 3350

225158